Research  >  Research  >  Labs & groups  >  Cardiovascular MRI  >  Introduction to MR physics  >  References
PAGE
MENU

References

MR physics: References

  1. F. Bloch, "Nuclear induction," Physical Review, vol. 70, pp. 460--473, 1946.
  2. E. Purcell, H. Torrey, and R. Pound, "Resonance absorption by nuclear magnetic moments in a solid," Physical Review, vol. 69, pp. 37--38, 1946.
  3. A. Garroway, P. Grannell, and P. Mansfield, "Image formation in NMR by a selective irradiative pulse," J. Phys. C: Solid State Phys., vol. 7, pp. L457--L462, 1974.
  4. P. Lauterbur, "Image formation by induced local interactions: Examples employing nuclear magnetic resonance," Nature, vol. 242, pp. 190--191, 1973.
  5. E. Hahn, "Spin echoes," Physical Review, vol. 80, pp. 580--594, 1950.
  6. S. Conolly, D. Nishimura, and A. Macovski, "Optimal control solution to the magnetic resonance selective excitation problem," IEEE Transactions on Medical Imaging, vol. MI-5, no. 2, pp. 106--115, 1986.
  7. J. Murdoch, A. Lent, and M. Kritzer, "Computer-optimized narrowband pulses for multislice imaging," Journal of Magnetic Resonance, vol. 74, pp. 226--263, 1987.
  8. J. M. Pauly, P. Le Roux, D. Nishimura, and A. Macovski, "Parameter relations for the Shinnar-Le Roux RF pulse design algorithm," IEEE Transactions on Medical Imaging, pp. 53--65, March 1991.
  9. J. Pauly, D. Nishimura, and A. Macovski, "A k-space analysis of small-tip-angle excitation," Journal of Magnetic Resonance, vol. 81, pp. 43--56, 1989.
  10. D. B. Tweig, "The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods," Medical Physics, vol. 10, no. 5, p. 610, 1983.
  11. A. Kumar, D. Welti, and R. R. Ernst, "NMR Fourier zeugmatography," Journal of Magnetic Resonance, vol. 18, pp. 69--83, 1975.
  12. R. Bracewell, The Fourier Transform and its Applications. San Francisco: McGraw-Hill Book Company, 1978.
  13. J. Hennig, A. Nauerth, and H. Friedburg, "RARE imaging: a fast imaging method for clinical MR," Magnetic Resonance in Medicine, vol. 3, pp. 823--833, 1986.
  14. A. Haase, "Snapshot FLASH MRI. Applications to T1, T2, and chemical-shift imaging," Magnetic Resonance in Medicine, vol. 13, no. 1, 1990.
  15. P. Mansfield, "Multi-planar image formation using NMR spin echoes," Journal of Physics C, vol. 10, pp. L55--L58, 1977.
  16. J. I. Jackson, C. H. Meyer, D. G. Nishimura, and A. Macovski, "Selection of a convolution function for Fourier inversion using gridding," IEEE Transactions on Medical Imaging, vol. 10, pp. 473--478, 1991.
  17. C. Meyer, B. Hu, D. Nishimura, and A. Macovski, "Fast spiral coronary artery imaging," Magn. Reson. Med., vol. 28, pp. 202--213, 1992.
  18. P. Bottomley, T. Foster, R. Argersinger, and L. Pfeifer, "A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and age," Medical Physics, vol. 11, no. 4, pp. 425--448, July/August 1984.
  19. E. McVeigh, M. Bronskill, and M. Henkelman, "Optimization of MR protocols: A statistical decision analysis approach," Magnetic Resonance in Medicine, vol. 6, pp. 314--333, 1988.
  20. P. Bottomley, C. Hardy, R. Argersinger, and G. Allen-Moore, "A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?," Medical Physics, vol. 14, pp. 1--37, Jan/Feb 1987.
  21. G. Wright, D. Nishimura, and A. Macovski, "Flow-independent magnetic resonance projection angiography," Magnetic Resonance in Medicine, vol. 17, no. 1, pp. 126--140, 1991.
  22. R. Gronas, P. Kalman, A. Kiruluta, and G. Wright, "Protocol optimization of flow-independent angiography for peripheral vascular disease," in Third Meeting of the Society of Magnetic Resonance, vol. 1, p. 75, August 1995.
  23. J. Brittain, E. Olcott, A. Szuba, P. Irarrazabal, G. Gold, G. Wright, and D. Nishimura, "Improvements for clinical 3D flow-independent peripheral angiography," in Fourth Meeting of the Society of Magnetic Resonance, vol. 1, p. 242, April 1996.
  24. G. Wright, B. Hu, and A. Macovski, "Estimating oxygen saturation of blood in vivo with MRI at 1.5 T," Journal of Magnetic Resonance Imaging, pp. 275--283, 1991.
  25. K. Li, G. Wright, L. Pelc, R. Dalman, J. Brittain, H. Wegmueller, D. Lin, and C. Song, "Oxygen saturation of blood in the superior mesenteric vein: In vivo verification of MR imaging measurements in a canine model," Radiology, vol. 194, no. 2, pp. 321--326, 1995.
  26. H. Nyquist, "Thermal agitation of electric charge in conductors," Physical Review, vol. 32, pp. 110--113, July 1928.
  27. S. Conolly, A. Macovski, and J. Pauly, "Magnetic resonance imaging: Acquisition and processing," in Biomedical Engineering Handbook (J. Bronzino, ed.), CRC Press, Inc., 1994.
  28. W. Edelstein, G. Glover, C. Hardy, and R. Redington, "The intrinsic signal-to-noise ratio in NMR imaging," Magnetic Resonance in Medicine, vol. 3, pp. 604--618, 1986.
  29. M. Bronskill and M. Henkelman, "Artifacts in magnetic resonance imaging," Reviews of Magnetic Resonance in Medicine, vol. 2, no. 1, 1987.
  30. M. Wood and M. Henkelman, "MR image artifacts from periodic motion," Medical Physics, vol. 12, no. 2, pp. 143--151, 1985.
  31. D. Bailes, D. Gilderdale, G. Bydder, A. Collins, and D. Firmin, "Respiratory ordered phase encoding (ROPE): A method for reducing respiratory motion artefacts in MR imaging," Journal of Computer Assisted Tomography, pp. 835--838, 1985.
  32. M. Wood, M. Shivji, and P. Stanchev, "Planar-motion correction with use of k-space data acquired in Fourier MR imaging," Journal of Magnetic Resonance Imaging, vol. 5, pp. 57--64, 1995.
  33. T. Sachs, C. Meyer, P. Irarrazabal, B. Hu, D. Nishimura, and A. Macovski, "The diminishing variance algorithm for real-time reduction of motion artifacts in MRI," Magn. Reson. Med., vol. 34, pp. 412--422, 1995.
  34. P. S. Melki, R. V. Mulkern, L. P. Panych, and F. A. Jolesz, "Comparing the FAISE method with conventional dual-echo sequences," Journal of Magnetic Resonance Imaging, vol. 1, pp. 319--326, 1991.
  35. H. Cline, W. Lorensen, R. Kikinis, and F. Jolesz, "Three-dimensional segmentation of MR images of the head using probability and connectivity," Journal of Computer Assisted Tomography, vol. 14, no. 6, pp. 1037--1045, 1990.
  36. J. Bezdek, L. Hall, and L. Clarke, "Review of MR image segmentation techniques using pattern recognition," Medical Physics, vol. 20, no. 4, pp. 1033--1048, 1993.
  37. L. Clarke, R. Vethuizen, M. Camacho, J. Heine, M. Vaidyanathan, L. Hall, R. Thatcher, and M. Silbiger, "MRI segmentation: Methods and applications," Magnetic Resonance Imaging, vol. 13, no. 3, pp. 343--368, 1995.
  38. P. van den Elsen, E. Pol, and M. Viergever, "Medical image matching - a review with classification," IEEE Engineering in Medicine and Biology, vol. 12, pp. 26--39, 1993.